Monitoring Sites - Wallaby Creek

Introduction | Contacts | Purpose | Site Description | Measurements | DEM | Pictures

Measurements

Measurements are being made at Wallaby Creek, Kinglake, Victoria, Australia.

Post Fire Instrumentation (May 2010-Current)

Instrument Type Make Model Situation
Open path CO2, H2O LI-COR LI-7500 Main mast, 5m
3D sonic anemometer
- wind velocities (u,v,w)
- sonic temperature
Campbell Scientific CSAT-3 Main mast, 5m mast
Net Radiometer Campbell Scientific NR-LITE Main mast, 5m
Diffuse Radiation Dynamax Inc. SPN1 Main mast, 5m
PAR Radiation Apogee Instruments Model MQ Main mast, 5m
Temperature Vaisala HMP45AC Main mast, 2m
Humidity Vaisala HMP45AC Main mast, 2m, 5m
Atmospheric Pressure Li-Cor LI-7500 Main mast, 5m
Soil temperature Campbell Scientific  TCAV-L Ground, -15cm
Soil heat flux (2 replicates) Hukesflux HFP01 Ground, -15cm
Soil moisture Campbell Scientific CS616 Ground, -15cm
Data Loggers Campbell Scientific CR-3000 Ground
Power Supply
- 12V DC EC flux station
Kyocera Solar panels (6) (BP) Two at each: 0.5, 1, 1.5m

Pre Fire Instrumentation (August 2005 - February 2009)

Instrument Type Make Model Situation
IRGA Open path
- density CO2, H2O
- atmospheric pressure
LI-COR LI-7500 25, 95m
3D sonic anemometer
- wind velocities (u,v,w)
- sonic temperature
Campbell CSAT-3 25, 95m
Air temperature, Humidity
- T, Rh
Vaisalla HMP-45C 2, 5, 10, 20, 45, 75m
PAR Radiation
- PPFD
- PPFD diffuse
AT Sunshine BF3 110m
Pyranometer Radiation
- Pyr
Kipp and Zonen CG2 110m
Albedometer Radiation
- Alb
Kip and Zonen CM 7B 110m
Net Radiation
- Rn
REBS Q7.1* 110m
Rainfall
- rain
Campbell CS702-L10m 0m
Wind direction, speed
- W dir , W vel
R M Young Wind sentry 110m
Soil temperature Thermocouple   -0.1,0.2,0.4,0.8,1.5m
5m from tower
Soil temperature
(averaging array)
Campbell TCAV -0.08m
50m from tower
Soil heat flux plates Campbell HFT3 -0.08m
5m from tower
Soil water content
(time domain reflectometer)
Campbell CS615 0.1,0.2,0.4,0.8,1.5m
5m from tower
Sap flow probes
- Granier method
Greenspan Tech       DBH
200m from tower
Automatic weather station
- temperature
- Relative Humidity Rh
    1.5m, situated 1.5 and 2km away from tower 300m
Data Loggers
- EC fluxes
- Tower profile
Campbell CR-5000
CR-10X
25, 95m  1m
Power Supply
- 12V DC EC flux station
Kyocera solar panels (4) (BP) 120W ea 60-80m

 

Modified: 7/10/21